• Hsr3-160 (APF) New Energy High Voltage DC Relay
  • Hsr3-160 (APF) New Energy High Voltage DC Relay
  • Hsr3-160 (APF) New Energy High Voltage DC Relay
  • Hsr3-160 (APF) New Energy High Voltage DC Relay
  • Hsr3-160 (APF) New Energy High Voltage DC Relay
  • Hsr3-160 (APF) New Energy High Voltage DC Relay

Hsr3-160 (APF) New Energy High Voltage DC Relay

Electricity Type: DC
Number of Pole: 8
Phase: 3
Main Circuit Rating Voltage: 12 24 48
Main Circuit Rating Current: 50A
Type: Dc Contactors
Samples:
US$ 20/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Gold Member Since 2021

Suppliers with verified business licenses

Trading Company
  • Overview
  • Product Description
Overview

Basic Info.

Model NO.
HSR3-160(APF)
Vibration
1A10Hz ~ 500Hz 49m/S2
Humidity
5% ~85% Rh
Temperature Range
-40ºC ~ +85ºC
Shock Resistance Stability
196m/S2
Transport Package
International Logistics
Specification
38.8*47.4
Origin
China
Production Capacity
10000PCS/Year

Product Description

Contact style
1A
Contact resistance
≤5mΩ (1A)
Contact material
AgSnO2
Contact load current
200A
Mechanical endurance
2×105 ops / 2×105
Maximum switching voltage
1000VAC
Maximum breaking current
30A (450VDC, more than 1 times) / 50A(450VDC)
Maximum switching power
1.8KW
Electrical durability (resistance)(1)
Breaking: 1×103 times(450VDC, 40A) / switchover
 : 1×103 times (450VDC, 40A)
Breaking: 1×104 times(450VDC, 10A) / switchover
: 1×104 times (450VDC, 10A)
Making: 7.5×104 times(450VDC, 35A) / connect
: 7.5×104 times (450VDC, 35A)
Current-carrying capacity(2)
20A: Conti. /30A:1h/40A:20min/80A:30s/120A:10s /200A:0.6s
Notes
1. Funless additonal statement, the temperature of electrical endurance is at 23ºC and
on-off ratio is 0.6s:5.4s.
2. The cross-sectional area of the wire is 4mm2 , and the test ambient temperature is 85ºC.
Insulation resistance
1000 mΩ (500 VDC)
Dielectric strength (Between coil & contacts)
3000VAC (50/60Hz,1min)
Dielectric strength (Between open contacts)
2000VAC (50/60Hz,1min)
Operate time (Rated voltage)
30ms
Release time (Rated voltage)
10ms
Shock resistance stability
196m/s2
Shock resistance strength
490m/s2
Vibration
10Hz ~ 500Hz 49m/s2
Humidity
5% ~85% RH
Temperature range
-40ºC ~ +85ºC
Terminal
QC/Quick connection type
Weight
About 59g / ~ 59g
Note
The above data are initial values. / The above data are initial values. /
Rated coil power
3W
 
Product Description
FEATURES
300A switching capability
Apply to Solar photovoltaic power inverter
Contact gap: 4mm
The contact on and off state is maintained by permanentmagnet, and the
switching only needs instantaneous excitation voltage
Energy saving and environmental friendly (ROHS compliance)
 
ATTENTIONS
Due to the impact of transportation or relay installation and other factors, the state may be changed, so please reset it to the reset state
or action state as required when using (when the power supply is connected);
In order to ensure the action or reset of the latching relay, the excitation voltage applied to the coil must reach the rated
voltage, and the pulse width must be greater than 5 times of the action or reset time; Do not apply voltage to the action coil and the
reset coil at the same time; Do not apply voltage to the coil for a long time (more than 1 minute);
This product is of anti-flux type, so it is recommended to store this product for less than 6 months and pay attention to the storage
environment.
To ensure the performance of the relay, please avoid the product from falling, collision and unnecessary impact.
For the coil drive mode of the product, please contact our technical department for confirmation.

CHIP DRIVE BL8023H is two-way relay drive integrated circuit, is used to control the bistable relay work, using CMOS process, the built-in fly-whel  diode,with large output current, the static characteristics oflow consumption, has been widely used in electric power industy products  such as smart meters, smart power capacitor, can also be used for other pulse, level conversion, etc.

ATTENTIONS
The factory status of the bistable relay is closed, but it may change due to the impact during transportation or installation. Therefore,
when using (when power in), please reset it to the reset state or action state as required;
In order to ensure the action or reset of the bistable relay , the excitation voltage applied to the coil must reach the rated voltage, and the
pulse duration must be greater than 5 times of the action or reset time; do not apply voltage to the action coil and the reset coil at the
same time; do not apply voltage to the coil for a long time (more than 1 minute);
The external parts are customized according to the special requirements of customers, so the recommended storage time is less than 6
months, and pay attention to the storage environment; at the same time, in order to ensure the product contact reliability, we will keep
the relay contact to the closed state without the customer's special declaration.
 
DECLARATION
All the specification listed only for customer's reference. It is subject to change without notice.
For us, it is impossible to evaluate all the performance parameters of the relay for every possible application, thus the user should
choose the corresponding products according to the specific conditions of their own application. Any doubt, please contact us for more
technical support. However, it is the user's responsibility to determine which product should be used only
Hsr3-160 (APF) New Energy High Voltage DC RelayHsr3-160 (APF) New Energy High Voltage DC RelayHsr3-160 (APF) New Energy High Voltage DC RelayHsr3-160 (APF) New Energy High Voltage DC RelayHsr3-160 (APF) New Energy High Voltage DC Relay
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2021

Suppliers with verified business licenses

Trading Company
Number of Employees
18
Year of Establishment
2015-07-24