Carbon Monoxide Detector Alarm Img_1142

Product Details
Customization: Available
Type: Carbon Monoxide Alarm
Signal Transmission: Standalone
Still deciding? Get samples of US$ 10/Piece
Request Sample
Gold Member Since 2021

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
18
Year of Establishment
2015-07-24
  • Carbon Monoxide Detector Alarm Img_1142
  • Carbon Monoxide Detector Alarm Img_1142
  • Carbon Monoxide Detector Alarm Img_1142
  • Carbon Monoxide Detector Alarm Img_1142
  • Carbon Monoxide Detector Alarm Img_1142
  • Carbon Monoxide Detector Alarm Img_1142
Find Similar Products

Basic Info.

Model NO.
1142
Working Mode
Active
Certification
RoHS, GS
Working Principle
Electromechanical
Transmission Mode
Cable
Alarm Volume (within 1m)
≥80dB
Color
White
Output
10000
Packaging
Carton
Source Area
Zhejiang Province
Transport Package
Carton
Production Capacity
10000

Product Description


Carbon Monoxide Alarm
User Manual
Model: DL-C101A
Carbon Monoxide Detector Alarm Img_1142

Ningbo Deli Electronics Co., Ltd.
Preface
Thank you for purchasing DL-C101A, an audible and visual carbon monoxide alarm equipped with LCD concentration display developed by our Company. Be sure to carefully read this product user manual prior to using to assist you in the proper usage.
    This alarm can only remind you of carbon monoxide hazard, but cannot prevent the occurrence of carbon monoxide. Please evacuate to safe areas and call professionals for treatment when hearing the alarm from the alarm.


Content Overview:
Chapter 1  Alarm Usage and Function Introduction
  1. DL-C101A Carbon Monoxide Alarm Usage
1.1  Electric Parameters of DL-C101A Carbon Monoxide Alarm
1.2  Brief Introduction to DL-C101A Carbon Monoxide Alarm
1.3  Battery Installation and Indications
1.3.1 Battery Installation
1.3.2 Battery Level Indication
1.3.3 Information Displayed on LCD Screen
    1.4  Alarm and Audio Indications
1.4.1 Sound and Light Indications
1.4.2 Alarm Status
1.4.3 Display of Carbon Monoxide Concentration Value

     1.5  Test and Mute Functions
1.5.1 Manual Test
1.5.2 Mute Functions

1.6 Sensor Failure Self-test Error Message and Treatment
1.6.1 Sensor Failure Test Message
1.6.2 Sensor Failure Treatment
1.7 Alarm Record View
1.7.1 Record Data Operation Options and Display
1.7.2 Alarm Record View and Purge
1.8 Alarm's End-of-life Warning

Chapter 2 Alarm Installation Instruction
2. DL-C101A Carbon Monoxide Alarm Installation
2.1 Select Installation Location
2.2 Installation Method
2.3 Installation Precautions

Chapter 3 Alarm Maintenance and Cleaning
3. Daily Maintenance and Precautions
3.1 Impact of Other Chemical Gases on Alarm
3.2 Alarm Cleaning and Maintenance
3.3 FAQ and Material Circumstance
3.4 Hazards from Unauthorized Disassembly and Repair

Chapter 4 Additional Information of Carbon Monoxide
4. Additional Information
4.1 Knowledge of Carbon Monoxide
4.2 How Carbon Monoxide Is Generated
4.3 Impact of Carbon Monoxide on Human Health
4.4 Threat of Carbon Monoxide on Families
4.5 Carbon Monoxide Poisoning Symptom
4.6 Carbon Monoxide Poisoning Treatment
4.7 How to Deal with Harmful Carbon Monoxide or Carbon Monoxide Alarm Alarms



Chapter 1 Alarm Usage and Function Introduction
  1. DL-C101A Carbon Monoxide Alarm Usage
    1. Electric Parameters of DL-C101A Carbon Monoxide Alarm
Effectively Detectable Gases: Carbon Monoxide
Detection Mode: Electrochemical Sensor
Dimensions:
Weight: 196 g (Battery included)
Type: Type B (Without Control Output)
Software Version: The version number in the product label paper   refers to the software release version number
Service Voltage: DC 4.5V (Three 1.5 V PAIRDEER LR6/AA High-energy Alkaline Batteries for 18 Months)
Low Voltage Indication: The alarm indications low voltage for voltage less than 3.5V, in which case the sensor only keeps 30 days of standby status or 2 hours of continuous alarm.
Work Environment: Temperature from 0ºC to 45ºC and relative humidity of 0-90%RH
Static Working Current: <35uA
Alarm Current:<85mA
Alarm Sound: >85dB (1M Distance)
Indication Concentration Range: 25-600PPM with error ±10%, "Hco" will display when the concentration over 600PPM.
Temperature Indication: -15-50ºC, the temperature and 0PPM must be indicated alternately about 22 seconds when CO concentration less than 25PPM.
Electric Quantity: Full, normal, low and shortage; Indicate 4 electric quantity states.

Carbon Monoxide Alarm Level: Execute EN50291 Standard
Carbon Monoxide Concentration Without Alarm Before With Alarm Before
33±3PPM 120 Minutes --
55±5ppm 60 Minutes 90 Minutes
110±10ppm 10 Minutes 40 Minutes
330±30ppm -- 3 Minutes


Remove Alarm Status: It is necessary to place the alarm in the air with CO concentration less than 40PPM after trigging and the alarm will be automatically removed within 6 minutes.
Power Indicator: Blink once every 45 seconds.
Failure Detection: Conduct self-inspection every two minutes.
Suitable Occasions: Home, hotel rooms, warehouses, basements
Effective Use Period: 10 years

Factory Accessories:
 
Serial No. Accessory Name Quantity
1 DL-C101A 1PC
2 Mounting Plate 1PC
3 AA Alkaline Battery 3PCS
4 Mounting Screw 2PCS
5 Plastic Expansion 2PCS

1.2 Brief Introduction to DL-C101A Carbon Monoxide Alarm
DL-C101A alarm`s basic function is only for the detection of carbon monoxide with the basic components as shown below.




Chapter 4 Additional Information of Carbon Monoxide
4. Additional Information
4.1 Knowledge of Carbon Monoxide
4.2 How Carbon Monoxide Is Generated
4.3 Impact of Carbon Monoxide on Human Health
4.4 Threat of Carbon Monoxide on Families
4.5 Carbon Monoxide Poisoning Symptom
4.6 Carbon Monoxide Poisoning Treatment
4.7 How to Deal with Harmful Carbon Monoxide or Carbon Monoxide Alarm Alarms



Chapter 1 Alarm Usage and Function Introduction
  1. DL-C101A Carbon Monoxide Alarm Usage
    1. Electric Parameters of DL-C101A Carbon Monoxide Alarm
Effectively Detectable Gases: Carbon Monoxide
Detection Mode: Electrochemical Sensor
Dimensions:
Weight: 196 g (Battery included)
Type: Type B (Without Control Output)
Software Version: The version number in the product label paper   refers to the software release version number
Service Voltage: DC 4.5V (Three 1.5 V PAIRDEER LR6/AA High-energy Alkaline Batteries for 18 Months)
Low Voltage Indication: The alarm indications low voltage for voltage less than 3.5V, in which case the sensor only keeps 30 days of standby status or 2 hours of continuous alarm.
Work Environment: Temperature from 0ºC to 45ºC and relative humidity of 0-90%RH
Static Working Current: <35uA
Alarm Current:<85mA
Alarm Sound: >85dB (1M Distance)
Indication Concentration Range: 25-600PPM with error ±10%, "Hco" will display when the concentration over 600PPM.
Temperature Indication: -15-50ºC, the temperature and 0PPM must be indicated alternately about 22 seconds when CO concentration less than 25PPM.
Electric Quantity: Full, normal, low and shortage; Indicate 4 electric quantity states.

Carbon Monoxide Alarm Level: Execute EN50291 Standard
Carbon Monoxide Concentration Without Alarm Before With Alarm Before
33±3PPM 120 Minutes --
55±5ppm 60 Minutes 90 Minutes
110±10ppm 10 Minutes 40 Minutes
330±30ppm -- 3 Minutes


Remove Alarm Status: It is necessary to place the alarm in the air with CO concentration less than 40PPM after trigging and the alarm will be automatically removed within 6 minutes.
Power Indicator: Blink once every 45 seconds.
Failure Detection: Conduct self-inspection every two minutes.
Suitable Occasions: Home, hotel rooms, warehouses, basements
Effective Use Period: 10 years

Factory Accessories:
 
Serial No. Accessory Name Quantity
1 DL-C101A 1PC
2 Mounting Plate 1PC
3 AA Alkaline Battery 3PCS
4 Mounting Screw 2PCS
5 Plastic Expansion 2PCS

1.2 Brief Introduction to DL-C101A Carbon Monoxide Alarm
DL-C101A alarm`s basic function is only for the detection of carbon monoxide with the basic components as shown below.

Chapter 4 Additional Information of Carbon Monoxide
4. Additional Information
4.1 Knowledge of Carbon Monoxide
4.2 How Carbon Monoxide Is Generated
4.3 Impact of Carbon Monoxide on Human Health
4.4 Threat of Carbon Monoxide on Families
4.5 Carbon Monoxide Poisoning Symptom
4.6 Carbon Monoxide Poisoning Treatment
4.7 How to Deal with Harmful Carbon Monoxide or Carbon Monoxide Alarm Alarms



Chapter 1 Alarm Usage and Function Introduction
  1. DL-C101A Carbon Monoxide Alarm Usage
    1. Electric Parameters of DL-C101A Carbon Monoxide Alarm
Effectively Detectable Gases: Carbon Monoxide
Detection Mode: Electrochemical Sensor
Dimensions:
Weight: 196 g (Battery included)
Type: Type B (Without Control Output)
Software Version: The version number in the product label paper   refers to the software release version number
Service Voltage: DC 4.5V (Three 1.5 V PAIRDEER LR6/AA High-energy Alkaline Batteries for 18 Months)
Low Voltage Indication: The alarm indications low voltage for voltage less than 3.5V, in which case the sensor only keeps 30 days of standby status or 2 hours of continuous alarm.
Work Environment: Temperature from 0ºC to 45ºC and relative humidity of 0-90%RH
Static Working Current: <35uA
Alarm Current:<85mA
Alarm Sound: >85dB (1M Distance)
Indication Concentration Range: 25-600PPM with error ±10%, "Hco" will display when the concentration over 600PPM.
Temperature Indication: -15-50ºC, the temperature and 0PPM must be indicated alternately about 22 seconds when CO concentration less than 25PPM.
Electric Quantity: Full, normal, low and shortage; Indicate 4 electric quantity states.

Carbon Monoxide Alarm Level: Execute EN50291 Standard
Carbon Monoxide Concentration Without Alarm Before With Alarm Before
33±3PPM 120 Minutes --
55±5ppm 60 Minutes 90 Minutes
110±10ppm 10 Minutes 40 Minutes
330±30ppm -- 3 Minutes


Remove Alarm Status: It is necessary to place the alarm in the air with CO concentration less than 40PPM after trigging and the alarm will be automatically removed within 6 minutes.
Power Indicator: Blink once every 45 seconds.
Failure Detection: Conduct self-inspection every two minutes.
Suitable Occasions: Home, hotel rooms, warehouses, basements
Effective Use Period: 10 years

Factory Accessories:
 
Serial No. Accessory Name Quantity
1 DL-C101A 1PC
2 Mounting Plate 1PC
3 AA Alkaline Battery 3PCS
4 Mounting Screw 2PCS
5 Plastic Expansion 2PCS

1.2 Brief Introduction to DL-C101A Carbon Monoxide Alarm
DL-C101A alarm`s basic function is only for the detection of carbon monoxide with the basic components as shown below.






 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier